B32932 ... B32936
AC applications (heavy duty series) / 305 V AC
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k0 values
Lead spacing (mm)
dV/dt (V/µs)
k0 (V2/µs)
15
25
30000
22.5
15
18000
27.5
12
15000
37.5
10
12000
Please read Cautions and warnings and
Important notes at the end of this document.