4. Modes of Operation
Figure 4-1. Modes of Operation
b
e
Unpowered Mode
VBatt = 0V
b
a
Fail-safe Mode
VCC: 3.3V/5V
with undervoltage monitoring
Communication: OFF
Watchdog: ON
a: VS > 5V
b: VS < 3.7V
c: Bus wake-up event
d: Wake up from WAKE or KL_15 pin
e: NRES switches to low
b
b
c+d+e
EN = 1
Normal Mode
VCC: 3.3V/5V
with undervoltage
monitoring
Communication: ON
Watchdog: ON
EN = 0
TXD = 1
EN = 1
EN = 0
TXD = 0
Go to silent command
Local wake-up event
Go to sleep command
EN = 1
c+d
Silent Mode
VCC: 3.3V/5V
with undervoltage monitoring
Communication: OFF
Watchdog: OFF
Sleep Mode
VCC: switched off
Communication: OFF
Watchdog: OFF
Table 4-1. Table of Modes
Mode of
Operation
Transceiver
Fail-safe
Off
Normal
On
Silent
Off
Sleep
Off
VCC
3.3V/5V
3.3V/5V
3.3V/5V
0V
Watchdog WD_OSC INH
On
1.23V On
On
1.23V On
Off
0V
Off
Off
0V
Off
RXD
High,
except after wake-up
LIN depending
High
0V
LIN
Recessive
TXD
depending
Recessive
Recessive
4.1 Normal Mode
This is the normal transmitting and receiving mode of the LIN Interface in accordance with the LIN specification LIN 2.x. The
voltage regulator is active and can source up to 85mA. The undervoltage detection is activated. The watchdog needs a
trigger signal from NTRIG to avoid resets at NRES. If NRES is switched to low, the IC changes its state to Fail-safe Mode.