3.12 Modes of Operation
Figure 3-1. Modes of Operation
Unpowered Mode, VBat = 0V
b
a
b
b
Pre Normal Mode
VCC: 5V/50 mA with undervoltage reset
Communication: OFF
b
c+d
EN = 1
Normal Mode
VCC: 5V ±2%/50 mA
with undervoltage
reset
Communication: On
EN = 0
TXD = 1
EN = 0
EN = 0
TXD = 0
EN = 1
Go to silent command
Local wake-up event
Go to sleep command
Local wake-up event
c+d
Normal Mode
VCC: 5V ±7%/50 mA
with undervoltage reset
Communication: OFF
Sleep Mode
VCC: switched off
Communication: Off
a: VS > 5V
b: VS < 4V
c: Bus wake-up event
d: Wake-up from wake-up switch
3.12.1
Normal Mode
This is the normal transmitting and receiving mode. The voltage regulator is in normal mode and
can source 50 mA. The undervoltage detection is activated. The watchdog needs a trigger signal
from PTRIG or NTRIG to avoid resets at NRES.
3.12.2
Silent Mode
A falling edge at EN while TXD is high switches the IC into Silent Mode. The TXD signal has to
be logic high during the Mode Select window (Figure 3-2 on page 7). For EN and TXD either two
independent outputs can be used, or two outputs from the same microcontroller port; in the sec-
ond case, the mode change is only one command. In Silent Mode, the transmission path is
disabled. Supply current from VBat is typically IVSsi = 40 µA with no load at the VCC regulator.
The overall supply current from VBat is the addition of 40 µA plus the VCC regulator output current
IVCCs.
6 ATA6621