datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

AQY210KSX 데이터 시트보기 (PDF) - Matsushita Electric Works

부품명
상세내역
일치하는 목록
AQY210KSX
Nais
Matsushita Electric Works Nais
AQY210KSX Datasheet PDF : 4 Pages
1 2 3 4
AQY210KS
What is short circuit protection?
When the load current exceeds specifica-
tions, the short circuit protection function
kicks in and completely cuts off the load
current, thus turning off the relay.
The short circuit protection inside the
PhotoMOS relay instantaneously
(typ. 50 µs) and completely cuts of the
load current.
This protects any circuits that follow the
PhotoMOS relay from excess current.
There is almost no heating of the Photo-
MOS relay, which prevents it from becom-
ing damaged. To restore the function of
the relay turn off the input current and
then turn it back on.
Output voltage and output current
characteristics
V-I characteristics of PhotoMOS relay
with short circuit protection circuit
Output voltage
Operation chart
Relay input
current
5mA
0
Occurrence of
short circuit current
Abnormal current
120mA
Relay output
current
0
Normal relay operation
Detection time
(approx. 50 µs)
The short circuit current
detection device latches
when the relay is off.
The relay operates normally
when the input current is reset.
If the output section shorts even after
the input current is reset, it will latch
when the short circuit current is
detected again and the relay turns off.
51/70/02001
All Rights Reserved, © Copyright Matsushita Electric Works, Ltd.

Share Link: 