AD7641
Pin
No. Mnemonic
13
D6
or EXT/INT
14
D7
or INVSYNC
15
D8
or INVSCLK
16
D9
or RDC
or SDIN
17
OGND
18
OVDD
19
DVDD
20
DGND
21
D10
or SDOUT
22
D11
or SCLK
23
D12
or SYNC
24
D13
or RDERROR
Type 1
DI/O
DI/O
DI/O
DI/O
P
P
P
P
DO
DI/O
DO
DO
Description
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 6 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), serial clock source select. This input is used to select the
internally generated (master) or external (slave) serial data clock.
When EXT/INT = low, master mode. The internal serial clock is selected on SCLK output.
When EXT/INT = high, slave mode. The output data is synchronized to an external clock signal,
gated by CS, connected to the SCLK input.
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 7 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), invert sync select. In serial master mode (EXT/INT = low), this
input is used to select the active state of the SYNC signal.
When INVSYNC = low, SYNC is active high.
When INVSYNC = high, SYNC is active low.
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 8 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), invert SCLK select. In all serial modes, this input is used to
invert the SCLK signal.
When MODE[1:0] = 0, 1, or 2, this output is used as bit 9 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), read during convert. When using serial master mode
(EXT/INT = low), RDC is used to select the read mode.
When RDC = high, the previous conversion result is output on SDOUT during conversion and
the period of SCLK changes (see the Master Serial Interface section).
When RDC = low (read after convert), the current result can be output on SDOUT only when
the conversion is complete.
When MODE[1:0] = 3, (serial mode), serial data in. When using serial slave mode, (EXT/INT = high),
SDIN could be used as a data input to daisy-chain the conversion results from two or more ADCs
onto a single SDOUT line. The digital data level on SDIN is output on SDOUT with a delay of 18 SCLK
periods after the initiation of the read sequence.
Input/Output Interface Digital Power Ground.
Input/Output Interface Digital Power. Nominally at the same supply as the supply of the
host interface (2.5 V or 3 V).
Digital Power. Nominally at 2.5 V.
Digital Power Ground.
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 10 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), serial data output. In serial mode, this pin is used as the serial
data output synchronized to SCLK. Conversion results are stored in an on-chip register. The AD7641
provides the conversion result, MSB first, from its internal shift register. The data format is
determined by the logic level of OB/2C.
In master mode, EXT/INT = low. SDOUT is valid on both edges of SCLK.
In slave mode, EXT/INT = high:
When INVSCLK = low, SDOUT is updated on SCLK rising edge and valid on the next falling edge.
When INVSCLK = high, SDOUT is updated on SCLK falling edge and valid on the next rising edge.
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 11 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), serial clock. In all serial modes, this pin is used as the serial
data clock input or output, depending upon the logic state of the EXT/INT pin. The active edge
where the data SDOUT is updated depends on the logic state of the INVSCLK pin.
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 12 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), frame synchronization. In serial master mode (EXT/INT= low),
this output is used as a digital output frame synchronization for use with the internal data clock.
When a read sequence is initiated and INVSYNC = low, SYNC is driven high and remains high
while SDOUT output is valid.
When a read sequence is initiated and INVSYNC = high, SYNC is driven low and remains low
while SDOUT output is valid.
When MODE[1:0] = 0, 1, or 2, this output is used as Bit 13 of the parallel port data output bus.
When MODE[1:0] = 3, (serial mode), read error. In serial slave mode (EXT/INT = high), this output
is used as an incomplete read error flag. If a data read is started and not completed when the
current conversion is complete, the current data is lost and RDERROR is pulsed high.
Rev. 0 | Page 9 of 28