ACS709
High Bandwidth, Fast Fault Response Current Sensor IC
In Thermally Enhanced Package
Setting Overcurrent Fault Switchpoint
The VOC needed for setting the overcurrent fault
switchpoint can be calculated as follows:
VOC = Sens × | IOC | ,
where VOC is in mV, Sens in mV/A, and IOC (overcur-
rent fault switchpoint) in A.
| Ioc | is the overcurrent fault switchpoint for a bi-
directional (AC) current, which means a bi-directional
device will have two symmetrical overcurrent fault
switchpoints, +IOC and –IOC .
See the following graph for IOC and VOC ranges.
IOC
0.4 VCC / Sens
0.25 VCC / Sens
0
– 0.25 VCC / Sens
– 0.4 VCC / Sens
IOC versus VOC
(20BB and 35BB Versions)
Not in Valid Range
In Valid Range
0. 25 VCC
0. 4 VCC
VOC
Example: For ACS709LLFTR-35BB-T, if required overcurrent fault switchpoint is 50 A, and VCC = 5 V, then the
required VOC can be calculated as follows:
VOC = Sens × IOC = 28 × 50 = 1400 (mV)