Philips Semiconductors
BCD to 7-segment latch/decoder/driver
Product specification
74HC/HCT4511
FEATURES
Latch storage of BCD inputs
Blanking input
Lamp test input
Driving common cathode LED displays
Guaranteed 10 mA drive capability per output
Output capability: non-standard
ICC category: MSI
GENERAL DESCRIPTION
The 74HC/HCT4511 are high-speed Si-gate CMOS
devices and are pin compatible with “4511” of the “4000B”
series. They are specified in compliance with JEDEC
standard no. 7A.
The 74HC/HCT4511 are BCD to 7-segment
latch/decoder/drivers with four address inputs (D1 to D4),
an active LOW latch enable input (LE), an active LOW
ripple blanking input (BI), an active LOW lamp test input
(LT), and seven active HIGH segment outputs (Qa to Qg).
When LE is LOW, the state of the segment outputs (Qa to
Qg) is determined by the data on D1 to D4.
When LE goes HIGH, the last data present on D1 to D4 are
stored in the latches and the segment outputs remain
stable.
When LT is LOW, all the segment outputs are HIGH
independent of all other input conditions. With LT HIGH, a
LOW on BI forces all segment outputs LOW. The inputs LT
and BI do not affect the latch circuit.
APPLICATIONS
Driving LED displays
Driving incandescent displays
Driving fluorescent displays
Driving LCD displays
Driving gas discharge displays
QUICK REFERENCE DATA
GND = 0 V; Tamb = 25 °C; tr = tf = 6 ns
SYMBOL
tPHL/ tPLH
CI
CPD
PARAMETER
propagation delay
Dn to Qn
LE to Qn
BI to Qn
LT to Qn
input capacitance
power dissipation capacitance per latch
CONDITIONS
TYPICAL
HC
HCT
CL = 15 pF; VCC = 5 V
24
24
23
24
19
20
12
13
3.5
3.5
notes 1 and 2
64
64
Notes
1. CPD is used to determine the dynamic power dissipation (PD in µW):
PD = CPD × VCC2 × fi + ∑ (CL × VCC2 × fo) where:
fi = input frequency in MHz
fo = output frequency in MHz
(CL × VCC2 × fo) = sum of outputs
CL = output load capacitance in pF
VCC = supply voltage in V
2. For HC the condition is VI = GND to VCC
For HCT the condition is VI = GND to VCC 1.5 V
UNIT
ns
ns
ns
ns
pF
pF