DC ELECTRICAL CHARACTERISTICS
LIMITS
SYMBOL
PARAMETER
TEST CONDITIONS
Tamb = +25°C
Tamb = –40°C
to +85°C
UNIT
Min Typ Max Min Max
VIK
Input clamp voltage
VOH High-level output voltage
VRST
Power-up output low
voltage3
VCC = 4.5V; IIK = –18mA
VCC = 4.5V; IOH = –3mA; VI = VIL or VIH
VCC = 5.0V; IOH = –3mA; VI = VIL or VIH
VCC = 4.5V; IOH = –32mA; VI = VIL or VIH
VCC = 5.5V; IO = 1mA; VI = GND or VCC
–0.9 –1.2
–1.2 V
2.5 3.2
2.5
V
3.0 3.7
3.0
V
2.0 2.3
2.0
V
0.13 0.55
0.55 V
VOL Low-level output voltage
VCC = 4.5V; IOL = 64mA; VI = VIL or VIH
0.42 0.55
0.55 V
IOFF
Power-off leakage current
VCC = 0.0V; VI or VO 4.5V
±5.0 ±100
±100 µA
IPU/IPD
Power–up/down 3-State
output current4
VCC = 2.1V; VO = 0.5V; VI = GND or VCC;
VOE = Don’t care
±5.0 ±50
±50 µA
II
Input leakage Control pins VCC = 5.5V; VI = GND or 5.5V
±0.01 ±1.0
±1.0 µA
current
Data pins
VCC = 5.5V; VI = GND or 5.5V
±5 ±100
±100 µA
IIH + IOZH 3-State output High current VCC = 5.5V; VO = 2.7V; VI = VIL or VIH
5.0 50
50
µA
IIL + IOZL 3-State output Low current VCC = 5.5V; VO = 0.5V; VI = VIL or VIH
–5.0 –50
–50 µA
ICEX
Output high leakage current VCC = 5.5V; VO = 5.5 V; VI = GND or VCC
5.0 50
50
µA
IO
Output current1
VCC = 5.5V; VO = 2.5V
–50 –65 –180 –50 –180 mA
ICCH
VCC = 5.5V; Outputs High, VI = GND or VCC
110 250
250 µA
ICCL Quiescent supply current
VCC = 5.5V; Outputs Low, VI = GND or VCC
20
30
30 mA
ICCZ
VCC = 5.5V; Outputs 3-State;
VI = GND or VCC
110 250
250 µA
ICC
Additional supply current per VCC = 5.5V; one input at 3.4V,
input pin2
other inputs at VCC or GND; VCC = 5.5V
0.3 1.5
1.5 mA
NOTES:
1. Not more than one output should be tested at a time, and the duration of the test should not exceed one second.
2. This is the increase in supply current for each input at 3.4V.
3. For valid test results, data must not be loaded into the flip-flops (or latches) after applying the power.
4. This parameter is valid for any VCC between 0V and 2.1V, with a transition time of up to 10msec. From VCC = 2.1 to VCC = 5V ± 10% a
transition time of up to 100µsec is permitted.
1998 Jun 08