1.2A, Current-Limited, High-Side
P-Channel Switch with Thermal Shutdown
MAX890L
SET
RSET
GND
Figure 2. Setting the Current Limit
Thermal Shutdown
The MAX890L features thermal shutdown. The switch
turns off when the junction temperature exceeds
+135°C. Once the device cools by 10°C, the switch
turns back on. If the fault short-circuit condition is not
removed, the switch cycles on and off, resulting in a
pulsed output.
Fault Indicator
The MAX890L provides a fault output (FAULT). This
open-drain output goes low when in current limit or
when the die temperature exceeds +135°C. A 100kΩ
pull-up resistor from FAULT to IN provides a logic-
control signal.
Applications Information
Input Capacitor
To limit the input voltage drop during momentary output
short-circuit conditions, connect a capacitor from IN to
GND. A 1µF ceramic capacitor is adequate for most
applications; however, higher capacitor values further
reduce the voltage drop at the input.
Output Capacitor
Connect a 0.1µF capacitor from OUT to GND. One
function of this capacitor is to prevent inductive para-
sitics from pulling OUT negative during turn-off.
Layout and Thermal-Dissipation
Consideration
To take full advantage of the switch-response time to
output short-circuit conditions, it is very important to
keep all traces as short as possible to reduce the effect
of undesirable parasitic inductance. Place input and
output capacitors as close as possible to the device
(no more than 5mm).
Under normal operating conditions, the package can
dissipate and channel heat away. Calculate the maxi-
mum power as follows:
P = I2LIMIT x RON
where RON is the on-resistance of the switch.
When the output is short circuited, the voltage drop
across the switch equals the input supply. Hence, the
power dissipated across the switch increases, as does
the die temperature. If the fault condition is not
removed, the thermal-overload-protection circuitry turns
the switch off until the die temperature falls by 10°C. A
ground plane in contact with the device helps dissipate
additional heat.
Package Information
For the latest package outline information and land patterns
(footprints), go to www.maxim-ic.com/packages. Note that a
“+”, “#”, or “-” in the package code indicates RoHS status only.
Package drawings may show a different suffix character, but the
drawing pertains to the package regardless of RoHS status.
PACKAGE
TYPE
8 SO
PACKAGE
CODE
S8+5
OUTLINE
LAND
NO. PATTERN NO.
21-0041
90-0096
_______________________________________________________________________________________ 7

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]