L3GD20
Digital main blocks
4.2.6
Retrieve data from FIFO
FIFO data is read through OUT_X (Addr reg 28h,29h), OUT_Y (Addr reg 2Ah,2Bh) and
OUT_Z (Addr reg 2Ch,2Dh). When the FIFO is in Stream, Trigger or FIFO mode, a read
operation of the OUT_X, OUT_Y or OUT_Z registers provides the data stored in the FIFO.
Each time data is read from the FIFO, the oldest pitch, roll and yaw data is placed in the
OUT_X, OUT_Y and OUT_Z registers and both single read and read_burst (X,Y & Z with
auto-incrementing address) operations can be used. When data included in OUT_Z_H
(2Dh) is read, the system restarts to read information from addr OUT_X_L (28h).