AD7606/AD7606-6/AD7606-4
Data Sheet
Parameter
Power Dissipation
Normal Mode (Static)
Normal Mode (Operational)7
Standby Mode
Shutdown Mode
Test Conditions/Comments
AD7606
fSAMPLE = 200 kSPS
AD7606
AD7606-6
AD7606-4
Min
Typ
Max
Unit
80
115.5
mW
100
142
mW
90
126
mW
75
111
mW
25
42
mW
10
31.5
µW
1See the Terminology section.
2 This specification applies when reading during a conversion or after a conversion. If reading during a conversion in parallel mode with VDRIVE = 5 V, SNR typically reduces by 1.5 dB
and THD by 3 dB.
3 LSB means least significant bit. With ±5 V input range, 1 LSB = 152.58 µV. With ±10 V input range, 1 LSB = 305.175 µV.
4 These specifications include the full temperature range variation and contribution from the internal reference buffer but do not include the error contribution from
the external reference.
5 Bipolar zero code error is calculated with respect to the analog input voltage. See the Analog Input Clamp Protection section.
6 Sample tested during initial release to ensure compliance.
7 Operational power/current figure includes contribution when running in oversampling mode.
Rev. D | Page 6 of 36