Parameter Measurement Information
VCC = 2.7V and 3.3V ±0.3V
Load Circuit
Test
tpd
tPLZ/tPZL
tPHZ/tPZH
S1
Open
6V
GND
Voltage Waveforms Setup and Hold Times
Voltage Waveforms Pulse Duration
tw
Input
1.5V
1.5V
2.7V
0V
Voltage Waveforms Enable and Disable Times
Voltage Waveforms Propagation Delay Times
INPUT
1.5V
tPLH
OUTPUT
1.5V
2.7V
1.5V
0V
tPHL VOH
1.5V
VOL
Figure 2. Load Circuit and Voltage Waveforms
Notes:
A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
C. All inputs pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50Ω, tr 2 ns, tf ≤ 2 ns.
D. The outputs are measured one at a time with one transition per measurement.
E. tPLZ and tPHZ are the same as tdis.
F. tPZL and tPZH are the same as tten.
G. tPLH and tPHL are the same as tpd.
.
Pericom Semiconductor Corporation
2380 Bering Drive • San Jose, CA 95131 • 1-800-435-2336 • Fax (408) 435-1100 • http://www.pericom.com