datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MAX8662 데이터 시트보기 (PDF) - Maxim Integrated

부품명
상세내역
일치하는 목록
MAX8662 Datasheet PDF : 34 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Power-Management ICs for
Single-Cell, Li+ Battery-Operated Devices
ELECTRICAL CHARACTERISTICS (Input Limiter and Battery Charger) (continued)
(VDC = 5V, VBAT = 4V, VCEN = 0V, VPEN_ = 5V, RPSET = 3k, RISET = 3.15k, CCT = 0.068µF, TA = -40°C to +85°C, unless otherwise
noted.) (Note 1)
PARAMETER
BATTERY CHARGER
BAT-to-SYS On-Resistance
SYMBOL
CONDITIONS
RBAT_REG VDC = 0V, VBAT = 4.2V, ISYS = 1A
MIN TYP MAX UNITS
40
80 m
BAT-to-SYS Reverse
Regulation Voltage
VDC = 5V, VPEN1 = VPEN2 = 0V (USB 100mA mode),
ISYS = 200mA (BAT to SYS voltage drop during SYS 50 100 150 mV
overload)
BAT Regulation Voltage
BAT Recharge Threshold
BAT Fast-Charge Current
BAT Prequalification Current
VBAT_REG
IBAT = 0mA
TA = +25°C
TA = -40°C to +85°C
BAT voltage drop to restart charging
ISYS = 0mA,
RPSET = 1.5k,
VPEN1 = VPEN2 = 5V
RISET = 1.89k
RISET = 3.15k
RISET = 7.87k
VBAT = 2.5V, RISET = 3.15k(prequalification
current is 10% of fast-charge current)
4.179 4.200 4.221
V
4.158 4.200 4.242
-140 -100 -60 mV
1250
675 750 825 mA
300
75
mA
ISET Resistance Range
RISET
Guaranteed by BAT charging current
(1.5A to 300mA)
1.57
7.87 k
VISET-to-IBAT Ratio
RISET = 3.15k(ISET output voltage to actual
charge-current ratio)
2
V/A
Charger Soft-Start Time
BAT Prequalification
Threshold
tSS_CHG
Charge-current ramp time
VBAT rising, 180mV hysteresis
1.5
ms
2.9 3.0 3.1
V
BAT Leakage Current
CHG and Top-Off Threshold
VBAT = 4.2V,
outputs disabled
IBAT where CHG goes
high, and top-off timer;
IBAT falling (7.5% of
fast-charge current)
VDC = 0V
VDC = VCEN = 5V
RISET = 3.15k
0.01
5
µA
0.01
5
56.25
mA
Timer-Suspend Threshold
Timer Accuracy
Prequalification Time
Charge Time
Top-Off Time
Charger Thermal-Limit
Temperature
Charger Thermal-Limit Gain
tPREQUAL
tFST-CHG
tTOP-OFF
IBAT falling (Note 3)
CCT = 0.068µF
From CEN high to end of prequalification charge,
VBAT = 2.5V, CCT = 0.068µF
From CEN high to end of fast charge,
CCT = 0.068µF
From CHG high to end of fast charge,
CCT = 0.068µF
(Note 4)
RPSET = 3k
250 300 350 mV
-20
+20 %
30
Min
300
Min
30
Min
100
°C
50
mA/°C
_______________________________________________________________________________________ 3