Current Transducer LB 200-S/SP4
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
IPN = 200 A
Electrical data
IPN
Primary nominal r.m.s. current
IP
Primary current, measuring range
RM Measuring resistance
with ± 15 V
@ ± 200 A max
@ ± 300 A max
ISN
Secondary nominal r.m.s. current
K N Conversion ratio
VC
Supply voltage (± 5 %)
IC
Current consumption
Vd
R.m.s. voltage for AC isolation test, 50 Hz, 1 mn
Accuracy - Dynamic performance data
εX G
L
Overall accuracy @ IPN, TA = 25°C
Linearity
IO
IOT
tr
di/dt
f
Offset current @ IP = 0, TA = 25°C
Thermal drift of IO
+ 20°C .. + 50°C
Response time 3) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
Output noise
Magnetization after excursion @ ± IPN
Crossing distortion
Matching specification
+ 20°C .. + 50°C
General data
TA
Ambient operating temperature
TS
Ambient storage temperature
R S Secondary coil resistance @ TA = 50°C
m
Mass
Standards 4)
200
A
0 .. ± 300
A
R R M min
M max
5
33
5
15
200
mA
1 : 1000
± 15
V
20 + IS
mA
6 1)
kV
1 2)
kV
± 0.5
%
< 0.1
%
Typ Max
± 0.50 mA
± 0.08 mA
<1
> 50
DC .. 150
< 0.002
< 0.01
negligeable
0.01
µs
A/µ s
kHz
mA
mA
mA
+ 20 .. + 50
°C
- 25 .. + 85
°C
30
200
g
EN 50178
Features
Closed loop (compensated) current
transducer using the Hall effect
Insulated plastic case recognized
according to UL 94-V0.
Special features
VC = ± 15 V (± 5 %)
K N = 1 : 1000
Shield
Negligeable zero crossing distortion
Low noise electronics
TA = + 20°C .. + 50°C
Low IOT
Transducers matched based on
thermal drift to within TA 0.01 mA.
Advantages
Better frequency response
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capability.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications.
Notes : 1) Between primary and secondary + shield.
2) Between secondary and shield.
3) With a di/dt of 100 A/µs
4) A list of corresponding tests is available.
990716/7