DC SWITCHING SERIES SPECIFICATIONS
DC60P or
DC60MP
DC200P or
DC200MP
DC60S-3
DC60S-5
Operating Voltage Range 5–60 VDC 5–200 VDC 5–60 VDC 5–60 VDC
Forward Voltage Drop
1.5 volts
at 3 amps
1.5 volts
at 1 amp
1.5 volts
at 3 amps
1.5 volts
at 5 amps
Nominal Current Rating
(Amps)
3*
1*
3*
5*
Off-State Blocking
60 VDC
250 VDC
60 VDC
60 VDC
Signal Pickup Voltage
3 VDC
32 Volts**
allowed
3 VDC
32 Volts**
allowed
3 VDC
32 Volts
allowed
3 VDC
32 Volts
allowed
Signal Dropout Voltage
1 VDC
1 VDC
1 VDC
1 VDC
Signal Input Impedance 1,000 ohms 1,000 ohms 1,000 ohms 1,000 ohms
1 Second Surge
5 amps
2 amps
5 amps
10 amps
Operating Temp. Range
–40 °C to
100 °C
–40 °C to
100 °C
–40 °C to
100 °C
–40 °C to
100 °C
Isolation Voltage
4,000 VRMS 4,000 VRMS 4,000 VRMS 4,000 VRMS
Off-State Leakage
1 mA
maximum
1 mA
maximum
1 mA
maximum
1 mA
maximum
Package Type
P/MP series P/MP series Power series Power series
Turn-on Time
100 usec
100 usec
100 usec
100 usec
Turn-off Time
750 usec
750 usec
750 usec
750 usec
Notes: * Ambient temperature will affect the current rating. For details, see the Thermal
Ratings chart.
** MP series maximum allowed control signal is 24 VDC.
NOTE: When controlling an inductive load, like a solenoid or coil, a commutating diode
must be used. Install the commutating diode across the terminals of the load (not the SSR
terminals). This will protect the SSR from damage caused by voltage spikes when turning off
the load.
Model DC60MP Basic Schematic (also applies to the other SSRs on this page)
DATA SHEET
Form 0859-180904
PAGE 11
Thermal Ratings
Ambient temperature will affect the current rating.
FREE AIR
MOUNTED ON A HEATSINK
WITH 2 °C/WATT RATING
Control Current varies with control voltage. For details, see “Control Current Calculation” on page 17.
OPTO 22 • 800-321-6786 • 1-951-695-3000 • www.opto22.com • sales@opto22.com
© 2006–2018 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]