datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

SL2410 데이터 시트보기 (PDF) - System Logic Semiconductor

부품명
상세내역
일치하는 목록
SL2410
System-Logic
System Logic Semiconductor System-Logic
SL2410 Datasheet PDF : 6 Pages
1 2 3 4 5 6
SL2410
ELECTRICAL CHARACTERISTICS(Voltages Referenced to GND, TA = -45 to +65°C)
Guaranteed Limits
Symbol
Parameter
Test Conditions
Min Typ Max
Unit
VSI
Initiation Supply Voltage See Fig. 1
(1)
16.8
21.2
V
ISI
Initiation Supply Current
(1)
1.4
4.2
mA
VSUS Sustaining Voltage (2)
See Fig. 1
9.5
ISUS Sustaining Current (2)
No Load VCC=VSUS
0.7
See Fig. 1
12.2
V
2.5
mA
VTR Trigger Voltage (3)
ITR
Trigger Current (3,5)
VDIS Disable Voltage (4)
IDIS
Disable Current (4)
VOH High-Level Output
Voltage
VCC=15V
8.8
VCC=15V
5.0
VCC=21V
-
VCC=15V
-20
VCC=21V, IOH=-15mA, Pin
16.7
6=6V, Pin 7=GND
12.2
V
1000
µA
0.7
V
-
µA
21.0
V
VOL Low-Level Output
Voltage
VCC=21V, IOL=15mA, Pin
-
6=GND, Pin 7=6V
1.8
V
IIN
Maximun Input Leakage Pin 3=6V,
-
Current
(Pin 3)
Pin 4=GND, VCC=21V
(Pin 7)
Pin 7=6V,
-
Pin 6=GND, VCC=21V
fH1
High Frequency 1
R3=191K,C3=6800pF
461
fH2
High Frequency 2
R3=191K,C3=6800pF
576
fL
Low Frequency
R2=165K, C2=0.47µF
9.0
1.0
µA
1.0
µA
563
Hz
704
Hz
11.0
Hz
Notes:
1. Initiation supply voltage (VSI) is the supply voltage required to start the tone ringer oscillating.
2. Sustaining voltage (VSUS) is the supply voltage required to maintain oscillation.
3. VTR and ITR are the conditions applied to trigger in to start oscillation for VSUSVCCVSI.
4. VDIS and IDIS are the conditions applied to trigger in to inhibit oscillation for VSIVCC.
5. Trigger current must be limited to this value ext ernally.
SLS
System Logic
Semiconductor

Share Link: 