6.1 MODULE 1 - Input Setup Parameters (1-INPUt)
1-INPUt
PARAMETER MENU
Dual Count
Pro
SEL
Dual Count or Batch
Only
or Batch
Only
INP A-b CntA dP CntA ScF CntA rSt CntA dir CntA Ld Cntb bAt Cntb dP Cntb ScF RSt P-UP USEr INP USEr ASN
Count
Mode
Counter A
Decimal Point
Counter A
Scale Factor
Counter A
Reset Action
Counter A
Count
Direction
Counter A
Count Load
Value
Counter B
Batch Count
Enable
Counter B
Decimal Point
Counter B
Scale Factor
Counter Reset
at Power-up
User Input
Function
User Input
Assignment
Shaded area selections only apply when Counter B is enabled (Dual Counter
mode or batch counter).
INP A-b
Cnt ud
COUNT MODE
Cnt ud qUAd 1
RAtE Cnt qUAd 2
dUAL Cnt qUAd 4
Add Add
Add Sub
Select the count mode that corresponds with your application. The input
actions are shown in the boxes below. For simple counting applications, it is
recommended to use Count with Direction for the count mode. Simply leave the
direction input unconnected.
DISPLAY
MODE
INPUT A ACTION
INPUT B ACTION
Cnt ud Count with Direction
Counter A
Counter A Direction
RAtE Cnt Rate/Counter
Rate only
Counter A Add
dUAL Cnt Dual Counter
Counter A Add
Counter B Add
qUAd 1 Quadrature x1
Count A
Quad A
qUAd 2 Quadrature x2
Count A
Quad A
qUAd 4 Quadrature x4
Count A
Quad A
Add Add 2 Input Add/Add
Counter A Add
Counter A Add
Add Sub 2 Input Add/Subtract
Counter A Add Counter A Subtract
Note: The Rate indicator signal is derived from Input A in all count modes.
COUNTER A DECIMAL POSITION
CntA dP
0
0 0.00 0.0000
0.0 0.000 0.00000
This selects the decimal point position for Counter A. The selection will also
affect Counter A scale factor calculations.
COUNTER A SCALE FACTOR
CmtA ScF
01.0000
00.0001 to 99.9999
The number of input counts is multiplied by the scale factor to obtain the
desired process value. A scale factor of 1.0000 will result in the display of the
actual number of input counts. (Details on scaling calculations are explained at
the end of this section.)*
COUNTER A COUNT LOAD VALUE
CmtA Ld
00000500
-9999999 to 99999999
Counter A resets to this value if Reset to Count Load action is selected.
COUNTER B BATCH COUNT ENABLE
Cmtb bAt
NO SP2
NO
SP1 SP1-2
The Counter B batch count function internally counts the number of output
activations of the selected setpoint(s). The count source for the batch counter
can be SP1, SP2 or both. Batch counting is available in all count modes except
Dual Counter, which uses an external input signal for Counter B. This
parameter only appears if a Setpoint Output option card is installed.
COUNTER B DECIMAL POSITION
Cntb dP
0
0 0.00 0.0000
0.0 0.000 0.00000
This selects the decimal point position for Counter B. The selection will also
affect Counter B scale factor calculations.
COUNTER B SCALE FACTOR
Cntb ScF 00.0001 to 99.9999
01.0000
The number of input or batch counts is multiplied by the scale factor to
obtain the desired process value. A scale factor of 1.0000 will result in the
display of the actual number of input or batch counts. (Details on scaling
calculations are explained at the end of this section.)*
COUNTER RESET AT POWER-UP
RSt P-UP
NO
NO Count  b
NO
yES Count A both A-b
COUNTER A RESET ACTION
CmtA rSt
to 2Ero
to 2Ero to CtLd
When Counter A is reset, it returns to Zero or Counter A Count Load value.
This reset action applies to all Counter A resets, except a setpoint generated
Counter Auto Reset programmed in Module 4.
The selected counter(s) will reset at each meter power-up.
* For value entry instructions, refer to selection/value entry in the Programming
The Meter section.
COUNTER A COUNT DIRECTION
CmtA dir
NOr
NOr rEV
Reverse (rEV) switches the normal Counter A count direction shown in the
Count Mode parameter chart.