PI74ALVCH16244
112233445566778899001122334455667788990011223344556677889900112211223344556677889900112233445566778899001122334455667788990011221122334455667788990011223344556677889900112213344655-66B7788i99t0011B2211u2233f44f55e66r7788D9900r11i22v3344e55r6677w8899i00t11h223334455-66S7788t99a00t11e2211O2233u4455t66p7788u9900t11s22
DC Electrical Characteristics-Continued (Over the Operating Range, TA = –40°C to +85°C, VCC = 3.3V ±10%)
Parameters
Description
Test Conditions(1)
Min. Typ.(2) Max.
IIN
Input Current
VIN = VCC or GND, VCC = 3.6V
±5
Units
VIN = 0.7V, VCC = 2.3V
45
IIN (HOLD)
Input
Hold
Current
VIN = 1.7V, VCC = 2.3V
–45
VIN = 0.8V, VCC = 3.0V
75
VIN = 2.0V, VCC = 3.0V
–75
VIN = 0 to 3.6V, VCC = 3.6V
±500
µA
IOZ
Output Current (3-State Outputs) VOUT = VCC or GND, VCC = 3.6V
±10
ICC
Supply Current
VCC = 3.6V, IOUT = 0µA,
VIN = GND or VCC
40
ICC
Supply Current per Input
@ TTL HIGH
VCC = 3.0V to 3.6V
One Input at VCC - 0.6V
Other Inputs at VCC or GND
750
Control Inputs
CI
Data Inputs
VIN = VCC or GND, VCC = 3.3V
3
6
pF
CO
Outputs
VO = VCC or GND, VCC = 3.3V
7
Notes:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 3.3V, +25°C ambient and maximum loading.
3. Unused Control Inputs must be held HIGH or LOW to prevent them from floating.
Switching Characteristics over Operating Range(1)
Parameters
From (INPUT)
To (OUTPUT)
VCC = 2.5V ± 0.2V
VCC = 2.7V VCC = 3.3V ± 0.3V
Min.(2)
Max. Min.(2) Max. Min.(2) Max. Units
tPD
tEN
tDIS
t/v(3)
A
Y
OE
Y
OE
Y
Description
Input Transition Rise or Fall
1.0
3.7
1.0
5.7
1.0
5.2
0
10
3.6
1.0
3.0
5.4
1.0
4.4
ns
4.6
1.0
4.1
0
10
0
10
ns/V
Notes:
1. See test circuit and waveforms.
2. Minimum limits are guaranteed but not tested on Propagation Delays.
3. Recommended operating condition.
Operating Characteristics, TA = 25ºC
Parameter
Test Conditions
VCC = 2.5V ± 0.2V VCC = 3.3V ± 0.3V Units
Typical
CPD Power Dissipation
Outputs Enabled
CL = 50pF
16
Capacitance
Outputs Disabled
f = 10 MHz
4
19
pF
5