Double Balanced Mixer, 10 - 1500 MHz
MD-/MDS-148
V 3.00
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Units
Min
Typ
Frequency Range
Conversion Loss
Isolation
DC Polarity
RF, LO Ports
IF Port
LO to RF
LO to IF
RF to IF
Negative
10 - 1500
DC - 1500
MHz
—
—
MHz
10 - 800 MHz
dB
—
—
800 - 1500 MHz
dB
—
—
10 - 100 MHz
dB
35
—
100 - 1000 MHz
dB
25
—
1000 - 1500 MHz
dB
20
—
10 - 100 MHz
dB
35
—
100 - 1000 MHz
dB
20
—
1000 - 1500 MHz
dB
12
—
10 - 100 MHz
dB
30
—
100 - 1000 MHz
dB
18
—
1000 - 1500 MHz
dB
8
—
—
—
—
—
DC Offset
—
—
mV
—
<10
RF Input
SSB Noise Figure
Typical Two-Tone IM
Ratio 2
1 dB Compression
1 dB Desensitization
Within 1 dB of Conversion Loss
Max
with a –10 dBm input, each input,
25 MHz and 35 MHz IF
—
—
—
1500 MHz
dBm
—
+5
dBm
—
+3
—
—
—
dB
—
50
1. All specifications apply when operated at +10 dBm available LO power with 50 ohm source and load impedance.
2. Measured at 1500 MHz.
Max
—
7.5
10
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Bottom View of SF-1
.385 Ref
.220
.165
4X .016 ± .002
.506
Typical Performance Curves
Conversion Loss
9
8
7
.381
6
.002
5
.000
10
20
50
100
200
500 1000 1500
Frequency (MHz)
Specifications subject to change without notice.
2
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.