MC-458CA727
DC Characteristics (Recommended Operating Conditions Unless Otherwise Noted)
Parameter
Symbol
Test condition
MIN. MAX. Unit Notes
Operating current
ICC1 Burst length = 1
/CAS latency = 2
550 mA
1
tRC tRC(MIN.), IO = 0 mA
/CAS latency = 3
575
Precharge standby current in ICC2P CKE VIL(MAX.), tCK = 15 ns
5
mA
power down mode
ICC2PS CKE VIL(MAX.), tCK =
5
Precharge standby current in ICC2N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
100 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC2NS CKE VIH(MIN.), tCK = , Input signals are stable.
40
Active standby current in
ICC3P CKE VIL(MAX.), tCK = 15 ns
25
mA
power down mode
ICC3PS CKE VIL(MAX.), tCK =
20
Active standby current in
ICC3N CKE VIH(MIN.), tCK = 15 ns, /CS VIH(MIN.),
150 mA
non power down mode
Input signals are changed one time during 30 ns.
ICC3NS CKE VIH(MIN.), tCK = , Input signals are stable.
100
Operating current (Burst mode) ICC4 tCK tCK(MIN.), IO = 0 mA
/CAS latency = 2
725 mA
2
/CAS latency = 3
925
CBR (Auto) refresh current
ICC5 tRC tRC(MIN.)
/CAS latency = 2
1,150 mA
3
/CAS latency = 3
1,200
Self refresh current
ICC6 CKE 0.2 V
10
mA
Input leakage current
II(L) VI = 0 to 3.6 V, All other pins not under test = 0 V
–5
+5
µA
Output leakage current
IO(L) DOUT is disabled, VO = 0 to 3.6 V
–1.5 +1.5 µA
High level output voltage
VOH IO = –4 mA
2.4
V
Low level output voltage
VOL IO = +4 mA
0.4
V
Notes 1. ICC1 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC1 is measured on condition that addresses are changed only one time during tCK (MIN.).
2. ICC4 depends on output loading and cycle rates. Specified values are obtained with the output open. In
addition to this, ICC4 is measured on condition that addresses are changed only one time during tCK (MIN.).
3. ICC5 is measured on condition that addresses are changed only one time during tCK (MIN.).