Low-Power, 1% Accurate, Dual-/Triple-/Quad-Level
Battery Monitors in Small TDFN and TQFN Packages
Monitoring a Battery Voltage Higher
than the Allowable VBATT
For monitoring higher voltages, supply a voltage to BATT,
which is within the specified supply range, and power the
input resistive divider from the high voltage to be moni-
tored. Do not exceed the Absolute Maximum Ratings.
Maintaining Reference Accuracy
Since the ground connection of the MAX6782–MAX6790
has a small series resistance, any current flowing into an
output flows to ground and causes a small voltage to
develop from the internal ground to GND. This has the
effect of slightly increasing the reference voltage. To mini-
mize the effect on the reference voltage, keep the total
output sink current below 3mA.
R1
BATT
IN_
LBO_
R2
MAX6782
REF MAX6783
MAX6784
MAX6785
HADJ_
GND
Adding External Capacitance to Reduce
Noise and Transients
If monitoring voltages in a noisy environment, add a
bypass capacitor of 0.1µF from BATT to GND as close
as possible to the device. For systems with large tran-
sients, additional capacitance may be required.
Reverse-Battery Protection
To prevent damage to the device during a reverse-battery
condition, connect the MAX6782–MAX6785 in the configu-
ration shown in Figure 6a or 6b. For the internal reverse-
battery protection to function correctly on the MAX6782–
MAX6790, several conditions must be satisfied:
• The connections to IN_/LBL_/LBH_ must be made to
the center node of a resistive divider going from
BATT to GND. The Thevenin equivalent impedance
of the resistive divider must not fall below 1kin
order to limit the current.
• HADJ_ (MAX6782–MAX6785 only) must either be
connected to GND or to the center node of a resis-
tive divider going from REF to GND.
• The outputs may only be connected to devices pow-
ered by the same battery as the MAX6782–
MAX6790.
Note that the MAX6782–MAX6790 will not protect other
devices in the circuit.
Additional Application Circuit
Figure 7 shows the MAX6786/MAX6787/MAX6788 in a
typical two-battery-level monitoring circuit.
A) FACTORY PRESET HYSTERESIS CONNECTION
R1
R2
R3
R4
1
BATT
IN_
LBO_
REF
HADJ_
MAX6782
MAX6783
MAX6784
MAX6785
GND
BATT
LBL1
LBO1
LBH1
MAX6786
MAX6787
MAX6788
LBL2
LBO2
LBH2
GND
B) EXTERNAL HYSTERESIS ADJUST CONNECTION
Figure 6. Internal Preset or Externally Adjusted Hysteresis
Connection
Figure 7. Two-Battery-Level Monitor Configuration