HI-201HS
Typical Performance Curves
80
V+ = +15V, V- = -15V
70
60
50
40
125oC
25oC
30
-55oC
20
10
0
-15
-10
-5
0
5
10
15
ANALOG INPUT (V)
FIGURE 3. ON RESISTANCE vs ANALOG SIGNAL LEVEL
80
TA = 25oC
70
V+ = +8V, V- = -8V
60
V+ = +10V, V- = -10V
50
40
30
V+ = +12V, V- = -12V
20
V+ = +15V, V- = -15V
10
0
-15
-10
-5
0
5
10
15
ANALOG INPUT (V)
FIGURE 4. ON RESISTANCE vs ANALOG SIGNAL LEVEL
100.0
100.0
10.0
10.0
1.0
1.0
0.10
0.10
0.01
25
75
125
TEMPERATURE (oC)
0.01
25
75
125
TEMPERATURE (oC)
FIGURE 5. IS(OFF) OR ID(OFF) vs TEMPERATURE †
FIGURE 6. ID(ON) vs TEMPERATURE †
† Theoretically, leakage current will continue to decrease below 25oC. But due to environmental conditions, leakage measurements below this
temperature are not representative of actual switch performance.
7
V+ = +15V, V- = -15V
6
5
I+
4
I-
3
2
1
0
-55 -35 -15
5 25 45 65
TEMPERATURE (oC)
85 105 125
FIGURE 7. SUPPLY CURRENT vs TEMPERATURE
100
80 V+ = +15V, V- = -15V
60 IS(OFF) → VD = 0V
40 ID(OFF) → VS = 0V
20
0
IDON
-20
-40
-60
IS(OFF) / ID(OFF)
-80
-100
-120
-140
-160
-180
-200
-14 -12 -10 -8 -6 -4 -2 0 2 4 6
ANALOG INPUT (V)
8 10 12 14
FIGURE 8. LEAKAGE CURRENT vs ANALOG INPUT VOLTAGE