ULN2803,04AP/AFW
RECOMMENDED OPERATING CONDITIONS (Ta = −40~85°C)
CHARACTERISTIC
SYMBOL
TEST CONDITION
MIN TYP. MAX UNIT
Output Sustaining Voltage
Output Current
AP
AFW
Input Voltage
Input Voltage
(Output On)
ULN2803AP
/ AFW
ULN2804AP
/ AFW
Clamp Diode Reverse Voltage
Clamp Diode Forward Current
Power Dissipation
AP
AFW
VCE (SUS)
0
Tpw = 25 ms, Duty = 10%,
8 Circuits
0
Tpw = 25 ms, Duty = 50%,
8 Circuits
0
IOUT
Tpw = 25 ms, Duty = 10%,
8 Circuits
0
Tpw = 25 ms, Duty = 50%,
8 Circuits
0
VIN
0
3.5
VIN (ON)
8
VR
IF
Ta = 85°C
PD
Ta = 85°C
―
―
―
(Note) ―
―
50
V
―
347
―
123
mA /
ch
―
268
―
90
―
30
V
―
30
V
―
30
―
50
V
―
400 mA
― 0.76
W
― 0.48
Note: On Glass Epoxy PCB (75 × 114 × 1.6 mm Cu 20%)
3