Cermetek Microelectronics, Inc.
PHONE LINE CONNECTION GUIDELINES
1. The CH1782A must be mounted in the final
assembly such that it is isolated from exposure to
any hazardous voltages within the assembly.
Adequate separation and restraint of cables and
cords must be provided.
2. The circuitry from the CH1782A to the telephone
line interface must be provided in wiring that
carries no other circuitry other than that
specifically allowed in the FCC rules (such as A
and A1 leads).
3. Connection to phone line should be made
through an RJ-11C jack.
4. PCB traces from the modem’s RING and TIP pins
to the RJ-11C jack must be 0.1 inch spacing or
greater to one another and 0.2 inch spacing or
greater to all other traces. The traces should
have a nominal width of 0.020 inches or greater.
5. The RING and TIP PCB traces should be as
short as possible and oriented to prevent
coupling other high speed or high frequency
signals present on the host circuit PCB.
6. No additional circuitry other than that shown in
Figure 7A or 7B may be connected between the
modem module and the RJ-11C jack. Doing so
will invalidate the FCC approval.
7. The CH1782A, the RJ-11C jack, the interfacing
circuitry and all PCB traces in between, must be
contained on a PCB with a 94 V-0 flammability
rating.
8. The supplied FCC registration label must be
applied visibly on the outside of the product.
9. The product’s User Manual must provide the user
with instructions for connection and use as
recommended in the FCC Registration Section
below.
CH1782A HANDLING AND ASSEMBLY
RECOMMENDATIONS
The CH1782A contains static-sensitive components
and should only be handled by personnel and in
areas that are properly protected against static
discharge. The two recommended mounting
techniques for physically connecting the CH1782A to
a PCB are discussed below.
Direct Soldering. The CH1782A may be wave
soldered. All CH1782A products are hermetically
sealed and will not be harmed by industry standard
wave soldering processes.
CH1782A Family of Ultra Small Modem Modules V.22bis-2400bps
Socketing. The socketing approach to mounting
eliminates cleaning and desoldering concerns. When
the socket is used, it must make a solid connection to
all pins. Failure to do so will cause unreliable or
intermittent operation. Also, steps should be taken to
assure that the module remains tightly seated in the
socket during shipping. Cermetek recommends using
sockets from Samtec. See Application Note # 130,
Summary of Recommended Suppliers.
FCC REGISTRATION
All products in the CH1782A family are registered
with the FCC (Federal Communications Commission)
under Part 68. To maintain the validity of the
registration, you must serve notice to the end user of
the products of several restrictions the FCC places on
the modem and its use.
In addition to restriction notification, the FCC requires
that Cermetek make all repairs to all products in the
CH1782A family. If repairs are necessary after
installation of the CH1782A in the end product and
the end product has been delivered to the end user,
the end product must be returned to the end product
supplier where the CH1782A can be removed and
then forward to Cermetek for repair. The following
notice is recommended and should be included in the
end product’s user manual.
FOR YOUR USER’S MANUAL
The FCC Part 68 rules require the following (or
equivalent) be provided to the end user of equipment
containing a DAA.
Type of Service. The (insert end product name) is
designed to be used on standard device telephone
lines. It connects tot he telephone line by means of a
standard jack called the USOC RJ-11C (or USOC
RJ45S). Connection to telephone-company-provided
coin service (central office implemented systems) is
prohibited. Connection to party lines service is
subject to state tariffs.
Changes in Attestation Procedure for Plugs and
Jacks. (Name of applicant) attests that the network
interface plugs or jacks used on this equipment
comply with and will continue to comply with the
mechanical requirements specified in Part 58, sub-
part F, specifically the dimensions, tolerances and
metallic plating requirements. The compliance of
these connectors will be assured by purchase
specifications and incoming inspection.
Documentation of such specifications and/ or
inspections will be provided to the FCC within 30
days of their request for the same.