Notes: 1. ICC depends on output load condition when the device is selected. ICC (max) is specified at the
output open condition.
2. One bank operation.
3. Input signals are changed once per one clock.
4. Input signals are changed once per two clocks.
5. Input signals are changed once per four clocks.
6. After power down mode, CLK operating current.
7. After power down mode, no CLK operating current.
8. After self refresh mode set, self refresh current.
9. Input signals are VIH or VIL fixed.
Capacitance (Ta = 25°C, VCC = 3.3 V ± 0.3 V)
Parameter
Symbol
Min
Max
Unit
Notes
Input capacitance (CLK)
CI1
4
8
pF
1, 2, 4
Input capacitance
CI2
4
8
pF
1, 2, 4
(Input except DQM)
Input capacitance (DQM)
CI3
2
5
pF
1, 2, 4
Output capacitance (DQ)
CO
2
5
pF
1, 2, 3, 4
Notes: 1. Capacitance measured with Boonton Meter or effective capacitance measuring method.
2. Measurement condition: f = 1 MHz, 1.4 V bias, 200 mV swing.
3. DQMB = VIH to disable Dout.
4. This parameter is sampled and not 100% tested.