datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

RM2-12V 데이터 시트보기 (PDF) - Panasonic Corporation

부품명
상세내역
일치하는 목록
RM2-12V Datasheet PDF : 4 Pages
1 2 3 4
Discontinued
4 GHz 2 FORM C
MICROWAVE RELAY
RM-RELAYS
28
1.102
12.4
.488
10.5
.413
mm inch
• Excellent high frequency characteristics
Isolation: Min. 40dB (at 4 GHz)
Insertion loss Max. 1.0dB (at 4 GHz)
V.S.W.R.: Max. 1.5 (at 4 GHz)
• High sensitivity in small size
Size: 28.0 x 12.4 x 10.5 mm 1.102 x .488 x .413 inch
Nominal operating power: 360 mW (single side stable type)
• Sealed construction for automatic cleaning
• Latching types are also available
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By HP4328A)
Rating
Nominal switch-
ing capacity
High frequency Isolation
characteristics Insertion loss
(Impedance 50) V.S.W.R.
Expected life
(min. opera-
tions)
Mechanical
Electrical
(at 20 cpm)
2 Form C
100 m
0.01 A 24 V DC
10 W
(at 1.2 GHz, Impedance 50)
Min. 40 dB (at 4 GHz)
Max. 1.0 dB (at 4 GHz)
Max. 1.5 (at 4 GHz)
5×106
3×105 (0.01 A 24 V DC)
1×105
(10 W at 1.2 GHz, Impedance 50)
Coil (at 25°C, 68°F)
Nominal operating power
Single side stable
360 mW
1 coil latching
250 mW
2 coil latching
500 mW
Remarks
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as “Initial breakdown voltage” section
*2 Detection current: 10mA
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms, detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
*6 Detection time: 10µs
Characteristics
Max. operating speed (at rated load)
Initial insulation resistance*1
20 cpm
Min. 100 Mat 500 V DC
Between open contacts
Initial
breakdown
Between contact and coil
voltage*2 Between contact and
earth terminal
500 Vrms for 1 min.
1,000 Vrms for 1 min.
500 Vrms for 1 min.
Operate time [Set time]*3 (at nominal voltage)
Approx. 6 ms
[Approx. 3ms]
Release time (without diode)[Reset time]*3
(at nominal voltage)
Approx. 3 ms
[Approx. 3ms]
Temperature rise
Max. 60°C with nominal coil
voltage across coil and at
nominal switching capacity
Shock resistance
Functional*4
Destructive*5
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
Vibration
resistance
Functional*6
Destructive
10 to 55 Hz
at double amplitude of 1.5 mm
10 to 55 Hz
at double amplitude of 2 mm
Conditions for operation,
transport and storage
Ambient temp.
(Not freezing and condensing
at low temperature)
Humidity
–40°C to 60°C
–40°F to 140°F
5 to 85% R.H.
Unit weight
Approx. 7 g .247 oz
TYPICAL APPLICATIONS ORDERING INFORMATION
• Measuring equipment (Attenuator circuits)
• Audio visual equipment
• Communication equipment
Ex. RM
2
L2
24V
Contact arrangement
2:2 Form C
Operating function
Nil: Single side stable
L: 1 coil latching
L2: 2 coil latching
Note: Standard packing; Carton: 20 pcs. Case 200 pcs.
Coil voltage (DC)
3, 4.5, 5, 6, 9, 12, 24 V
97