Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
PS12038
Intellimod™ Module
Application Specific IPM
25 Amperes/1200 Volts
Electrical and Mechanical Characteristics, Tj = 25°C unless otherwise specified
Characteristics
Symbol
Test Conditions
Min.
Typ. Max. Units
Control Sector
Circuit Current (Average)
Input ON Threshold Voltage
Input OFF Threshold Voltage
Input Pull-up Resistor
ID
IDB
Vth(on)
Vth(off)
Ri
Tj = 25°C, VD = 15V, VIN = 5V
Tj = 25°C, VD = VDB = 15V, VIN = 5V
Applied between
Input Terminal-inside Power Supply
50
mA
5
mA
0.8
1.4
2.0
Volts
2.5
3.0
4.0
Volts
50
k
PWM Input Frequency
Arm Shoot-through Blocking Time*
Input Interlock Sensing
Inverter DC-link IGBT Current
Sense Voltage Output Signal**
Inverter DC-link IGBT Current
Sense Voltage Output Limit**
Over-current Trip Level
fPWM
tDEAD
tint
Vamp 100%
Vamp 200%
Vamp 250%
Vamp 0%
OC
TC 100°C, Tj 125°C
Relates to Corresponding Inputs
TC = -20°C ~ 100°C
Relates to Corresponding Input
IC = IOP(100%), VD = 15V, Tj = 25°C
IC = IOP(200%), VD = 15V, Tj = 25°C
IC = IOP(250%), VD = 15V
IC = IOP(0%), VD = 15V
10
15
kHz
4.0
µS
100
ns
1.5
2.0
2.5
Volts
3.0
4.0
5.0
Volts
5.0
Volts
50
100
mV
39.0 46.5
— Amperes
Over-current Delay Time
tOC
Tj = 25°C
10
µS
Short-circuit Trip Level
SC
69.7
— Amperes
Short-circuit Delay Time
Trip Level
tSC
UVD
2
µs
11.0 12.0 12.75 Volts
Supply Circuit
Reset Level
Under-voltage
Trip Level
Protection
Reset Level
Delay Time
Fault Output Pulse Width***
Fault Output Current***
UVDr
UVDB
UVDBr
tdV
tFO
IFo(H)
TC = Tj = 25°C
Tj = 25°C
Open Collector Output
11.5 12.5 13.25 Volts
10.1 10.8 11.6 Volts
10.6 11.3 12.1 Volts
10
µS
1.0
1.8
mS
1
µA
Thermistor Resistance
Material Constant****
IFo(L)
RTO
β
TO = 25°C (298K)
T1 = 25°C, T2 = 50°C
15
mA
9.5
10
10.5
k
3450
K
* The dead-time has to be set externally by the CPU; it is not part of the ASIPM internal functions.
**Refer to the graph on next page.
***Fault output signalling is given only when the internal OC, SC, and UV protection circuits are activated. The OC, SC and UV protection (and fault output) operate for the lower arms only.
The OC and SC protection fault output is given in a pulse format while that of UV protection is maintained throughout the duration of the under-voltage condition.
**** T =
1
[ ] 1
β
ln
RT
RTO
+
1
TO
106