¡ Semiconductor
FEDL6786-03
MSM6786
Keyscan
Keyscan starts when the key state is changed or when the "Keyscan Start" command is written.
Scan continues until the "Keyscan Stop" command is written. (When powered on, the power-
ON reset sets at scan stop state.)
When 1 keyscan cycle (TSCN) ends, the INT signal becomes "H", so this signal can be used as an
interrupt flag, which is dependent on switching conditions of keys. The INT signal is reset when
either the LOAD pulse is input after key data is output, when the "Keyscan Stop" command is
set, or when a reset signal is applied.
TSCN
R0
R1
R2
R3
R4
INT
Scan Start Command Write Data Read Data Read
or Key Status Changed
Data Read Scan Stop Command
Write
Notes : 1. A recognition error may occur if 3 or more key switches are pressed at the same time.
(A switch that was not pressed is recognized as being pressed.) To properly
recognize 3 or more key switches as being pressed at the same time, serially insert
diodes at each switch. In order not to recognize 3 or more key switches as being
pressed at the same time, a possible approach is to program the software so that the
read data will be ignored when there are 3 or more ones in the data.
The device recognizes simultaneous pressing of 2 key switches. However, take Note
2 into consideration.
2. A change of key state is detected as a change in column input (C0 - C5). Therefore
even if multiple switches connected to the same column are pressed at the same time,
nothing will be detected as a change.