Table 8. AC Measurement Conditions
Parameter
VCC Supply Voltage
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
45
3.0 to 3.6V
30pF
≤10ns
0 to 3V
1.5V
M29W010B
55
2.7 to 3.6V
30pF
≤10ns
0 to 3V
1.5V
70 / 90
2.7 to 3.6V
100pF
≤10ns
0 to 3V
1.5V
Figure 6. AC Testing Input Output Waveform
3V
1.5V
0V
AI01417
Figure 7. AC Testing Load Circuit
0.8V
1N914
DEVICE
UNDER
TEST
3.3kΩ
OUT
CL = 30pF or 100pF
Table 9. Capacitance
(TA = 25 °C, f = 1 MHz)
Symbol
Parameter
CIN
Input Capacitance
COUT
Output Capacitance
Note: Sampled only, not 100% tested.
CL includes JIG capacitance
AI02762
Test Condition
VIN = 0V
VOUT = 0V
Min
Max
Unit
6
pF
12
pF