datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

MAX31865 데이터 시트보기 (PDF) - Maxim Integrated

부품명
상세내역
일치하는 목록
MAX31865
MaximIC
Maxim Integrated MaximIC
MAX31865 Datasheet PDF : 25 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MAX31865
RTD-to-Digital Converter
DRDY
The DRDY output goes low when a new conversion result
is available in the RTD Data Registers. When a read-
operation of the RTD Data Registers completes, DRDY
returns high.
Applications Information
For operation in noisy environments, a filter capacitor
may be placed across the RTDIN+ and RTDIN- inputs.
After an overvoltage or undervoltage fault, after a fault
detection cycle, or after enabling VBIAS, always allow for
the settling time of the input filter before restarting the
ADC. A delay time of at least five time constants plus an
additional 1ms (for the protection devices to stabilize) is
recommended to achieve specified accuracy.
Converting RTD Data Register
Values to Temperature
The ratiometric ADC conversion results found in the RTD
Data Registers can be converted to temperature with a
few calculations.
First, the Resistance of the RTD needs to be determined
with the following equation:
RRTD = (ADC Code x RREF)/215
DRDY
RTD REGISTER
CONTENTS
CONVERSION n
CONVERSION n+1
CONVERSION n+2
CS
SDO
SDI
Figure 9. DRDY Operation
Maxim Integrated
  18

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]